NH Intelliview IV - Case IH Pro 700

 

NH Intelliview IV - Case IH Pro 700

1. Importing a card

On your PC (USB stick) :

  • Upload your task from the platform
  • Insert on the key
  • Extract the TASKDATA folder from the .zip file, to do so, open the .zip file and move the TASKDATA folder to your USB flash drive.

  • You can delete the zip file

  • Unplug your USB flash drive

On your PC (PLM Module) :

  • On MyEasyFarm, export your map to CNH (AFS Connect or MyPLMconnect) and select the farm you want to send your map to.
  • Then go to the  of your CNH platform.
  • Select the "Company" tab and the "Data Files" sub-tab
  • Click on "Send" on the file you have just transferred
  • And finally, select the hardware to which you wish to send the task

On your console (in either case) :

  • Insert the USB into the switched-off terminal (if using a USB stick)
  • Start the terminal
  • Go to MENU
  • Click on ISOBUS
  • In the "TC Main" tab, select the Cultivator (and if necessary, the farm, field and task).
  • Select the tool present
  • Then click on "TC map" and assign a map to an isobus tool (or an element of the tool)
  • Make sure your products are correctly configured by going to "TC Product".
  • Check that the information is correct and click on the "product management" tab to ensure that the product name is entered correctly.
  • You can select the plotting level (which item will be displayed on your screen cover)
  • Then go to "Performance" to check that the reading of the recommendation is activated
  • Set your default dosages (outside the mapped area) and ensure that the dosages do not exceed the Min / Max dosages of your card.
  • Once all your layers are configured, you return to Performance> TC> TC Task and select Start or Resume (Pause to stop the task temporarily)

2. Exporting data to MyEasyFarm

To export data to MyEasyFarm, you must have created a colouring (called a path on this console) and a boundary. The colouring is done automatically when an ISOBUS implement is attached. If not, you have to save the path manually

On the console (regardless of the method)

  • Once all the work is done, insert a USB stick into the terminal (if you are using a USB stick),
  • Go to the MENU by clicking on BACK several times
  • Go to the Data Managersection
  • Click on Export
  • Then select the data to be exported. Use cn1 mode for task data. For parcel contours only, you should use isoxml.
  • Then select Export, top right

 

  • You can then find your files directly in MyEasyFarm!

3. Configuration :

To be able to modulate automatically, your Intelliview IV or AFS Pro 700 console must be enabled for modulation with the following options:

  • TC SC: Automatic management of part width section breaks
  • TC Geo: Automatic management of dose modulation

To be able to manage the parcel contours, the main screen (which can be customised) must be configured. The "Boundary" option must be displayed.

 

 

 

 

Share :

Other articles

Search the website

Thank you for downloading
MyEasyFarm Pitch Deck!

Press the button below to start your download.

Subscribe to our newsletter